2003 ICC ANSI A117.1 EBOOK

The specifications in this standard make sites, facilities, buildings and elements accessible to and usable by people with such physical disabilities as the inability . 31 Jul LEGALLY BINDING DOCUMENTUnited States of AmericaAll citizens and residents are hereby advised that this is a legally binding document. Trademarks: “ICC,” the International Code Council logo and “Accessible and Usable Buildings and Facilities (ICC/ANSI Al )” are trademarks of the.

Author: Nera Dogor
Country: Angola
Language: English (Spanish)
Genre: Marketing
Published (Last): 20 February 2016
Pages: 356
PDF File Size: 10.23 Mb
ePub File Size: 14.38 Mb
ISBN: 736-5-73331-687-2
Downloads: 7430
Price: Free* [*Free Regsitration Required]
Uploader: Juhn

2003 ICC Accessible and Usable Buildings and Facilities

Treads shall be 1 1 inches mm minimum in depth. This standard is intended for adoption by government agencies and by organizations setting model codes to achieve uniformity in the technical design criteria in building codes and other regulations.

The American National Standards Institute does not develop stan- dards and will in no circumstances give an interpretation of any Ameri- can National Qnsi. The force for pushing or pulling open doors other than fire doors shall be as follows: A lavatory complying with Sec- tion shall be permitted at the end of the clear- ance opposite the shower compartment a11.1 where shower controls are positioned.

Top loading machines shall have the door 2003 icc ansi a117.1 the laundry compartment 36 inches mm maximum above the floor.

Full text of “ANSI A (): Accessible and Usable Buildings and Facilities”

Changes in level greater 2003 icc ansi a117.1 V 2 inch 13 mm in height shall be ramped and shall comply with Sec- tion or Symbols of accessibility shall contrast with their backgrounds, with either a light symbol on a dark background or a dark sym- bol on a light background. Handset cords, if provided, shall 2003 icc ansi a117.1 29 inches mm minimum in length. Indicators shall be located above the car control panel or above the door.

Accessible car and van parking spaces shall comply with Section Ambulatory accessible compartments shall comply with Section Dispens- ers shall not be of a type that control delivery, or do not allow continuous paper flow. Where the reach depth exceeds 20 inches mmthe high forward reach shall be 44 inches 1 mm maximum, and the reach depth shall be 25 inches mm maximum.

Table of Contents | ICC publicACCESS

Control buttons shall be identified by tactile characters complying with Section Urinals shall be of the stall type or shall be of the wall hung type with the rim at 17 inches mm maximum above the floor. This American National Standard may be revised or withdrawn at any time. General Site and Building Elements 20 feet min 60 min area to be marked Fig. The rise for any ramp run shall be 30 inches mm maximum.

The slope that is perpendicular to the 2003 icc ansi a117.1 of travel see running slope.

Destination oriented elevator systems shall not be required to comply with Section The Type B units are intended to supplement, 2003 icc ansi a117.1 replace, Accessible units or Type A units as speci- fied in this standard. A single unit providing complete, independent living facilities for one or more persons including permanent provisions for living, sleeping, eating, cooking and 2003 icc ansi a117.1. Where pro- vided, telephone directories shall comply with Section The running slope of walking surfaces shall not be steeper than 1: The level of illumination at the car controls, platform, and car threshold and landing sill shall be 5 foot-candles 54 lux mini- mum.

Grab bars shall have a cross section complying with Section The detectable warning shall be located so the edge nearest the curb line is 6 inches mm to 8 inches mm from the curb line.

ICC/ANSI A117.1 – 2003 (Accessible and Usable Buildings and Facilities)

Grab bars, and any wall or other surfaces adjacent to grab bars, shall be free of sharp or abrasive elements. The provisions of Chapter 3 shall apply where required by the scoping provisions adopted by the administrative authority or by Chap- ters 4 through Receivers required 2003 icc ansi a117.1 be hearing aid compatible shall interface with telecoils in hearing aids through the provision of neck loops.

Characters and their background shall have a nonglare finish. Communication Elements and Features Plumbing Elements and Facilities roll-in-type showers where a seat is provided, if the seat extends over the minimum clear inside dimen- sion required by Section Hand operated flush controls shall comply with Sections ICC 2003 icc ansi a117.1 their contributions as well as those of the 2003 icc ansi a117.1 who, although not on the committee, provided valuable input during this update cycle.

Detectable warning sur- faces shall be standard ahsi a building, facility, site, or complex of buildings. Objects beneath hall call buttons shall protrude 1 inch 25 mm maximum.

Emergency con- trols, including the emergency alarm, shall be grouped at the bottom of the panel. Parking spaces for vans, access aisles serving them, and vehicular routes from an entrance to the van parking spaces, and 2003 icc ansi a117.1 the van parking spaces to a vehicular exit serv- ing them shall provide a amsi clearance of 98 inches mm minimum.

Individual Expert IE Nonvoting – Members in this category are individual experts selected to assist the consensus body.

Each operable part shall be able to be differentiated by sound or touch, without acti- vation.